CFP AlarmSense 4 zone two-wire panel. Max  2 x 3.2Ah batteries

SKU: XN01-CFP704-2 Incoming stock
Key features
  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
  • Manufactured by C-TEC in the UK.
  • Four AlarmSense zone circuits - compatible with Apollo's AlarmSense detectors, call points, sounders and visual indicators.
  • Four conventional sounder circuits.
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  • Two on-board relays (Fire and Fault).
  • Two open-collector outputs (Remote and Reset).
  • 'Class change' and alert inputs.
  • Installer-friendly design.
  • Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
  • Low 25mA quiescent current.
  • Multiple indicators.
  • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
  • Space for two x 12V 3.3Ah VRLA batteries.
  • Show all product specifications Show Less
    fast delivery Delivery in 1-2 days (Ireland)
    refund 30 days Exchange or Refund

    Product specifications printPrint

    Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
    Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
    Manufactured by C-TEC in the UK.
    Four AlarmSense zone circuits - compatible with Apollo's AlarmSense detectors, call points, sounders and visual indicators.
    Four conventional sounder circuits.
    Integral 1.5A EN54-4/A2 compliant switch mode PSU.
    Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
    Two on-board relays (Fire and Fault).
    Two open-collector outputs (Remote and Reset).
    'Class change' and alert inputs.
    Installer-friendly design.
    Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
    Low 25mA quiescent current.
    Multiple indicators.
    System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
    Space for two x 12V 3.3Ah VRLA batteries.

    Specification type

    • Input Voltage 12V DC